Skip to content
Back to the design archive

Engineering records / Engineering record / SERVICE-INTEGRATION-R1

Service Integration R1.

Study overview

Geometry, analysis and remaining engineering work for Service Integration R1.

Retained development study. Dimensions, names and checks belong to this revision—not automatically to the current retrofit system. Manufactured tanks are not offered. No installation instruction, certification or manufacturing release is represented.

Service Integration R1 / assembled
Concept rendering
View details

Source development view: service-integration-r1/views/assembled.png. Engineering study; no product rating is implied.

The source reasoning

Why this detail was investigated.

The source reasoning

The screen study and carrier/cassette study are now positioned in the current vessel/frame coordinates. The STEP assembly contains 95 solids. The screen is shown in its contained, unlocked inspection state; its capture and release actuation remain unresolved.

Read the research and limits

Research record

The detail behind
the study.

Source-linked work for this revision. Reported checks describe the stated model or test; physical qualification and applicability to the current retrofit remain separate.

Read the research and limits

The screen study and carrier/cassette study are now positioned in the current vessel/frame coordinates. The STEP assembly contains 95 solids. The screen is shown in its contained, unlocked inspection state; its capture and release actuation remain unresolved.

The full vertical bounding envelopes, with 30 mm horizontal margin, clear the modeled permanent structure and conservative 931 × 547 mm opening. This is a continuous-envelope check for vertical translation, not merely a few snapshots. It does not cover hoses, cables, omitted equipment, hands or lifting apparatus.

Cover above roofScreen liftCarrier lift
0 mm1410 mm1690 mm
500 mm1910 mm2190 mm
4572 mm5982 mm6262 mm

Travel places the lowest surface 50 mm above the assumed grade plane. The 0/500 mm cases are packaging assumptions; 4572 mm comes from the source load study and is not a released service depth. There is no complete riser model or proven lifting/reach arrangement.

The module guides end well below grade. A full-depth lifting/guide system, sleeve actuation, latch release, connector parking and controlled containment must be designed. Neither the box check nor the orange module placement proves no-entry service. Pump, Hub, independent sensors, partitions and connected hydraulics remain absent, so this is not the completed equipment layout.

service-layout-record.json gives transforms, travel and interference results. Sweep STEP files represent the 500 mm cover case. The Blender view uses a cutaway skin for inspection; the assembly STEP retains the complete skin.

Source and revision record

Source: service-integration-r1/READ-ME.md

Source SHA-256: fa826dc818f0f0c7793dc14d553fd60e5d4c569c19b9d3f3e4be32e17edd7f42

Geometry and images describe this development revision. Current product ratings and manufacturing release require separate qualification.

Return to the current product.

Explore the retrofit system and its compatibility, installation and service objectives.

Explore the retrofit