Roof Grillage R1.

Geometry, analysis and remaining engineering work for Roof Grillage R1.

Retained development study. Dimensions, names and checks belong to this revision—not automatically to the retrofit-only product. Manufactured tank shells are deferred. No installation instruction, certification or manufacturing release is represented.

The source reasoning

Why this detail was investigated.

The model applies 101.44 kPa to the complete 3.102 by 2.101 m projected roof, including the access closure. Applied load is 661.115 kN from those rounded dimensions. All vertical reactions balance this load.

Read the research and limits

Research record

The detail behind
the study.

Source-linked work for this revision. Reported checks describe the stated model or test; physical qualification and applicability to the current retrofit remain separate.

Preliminary roof load-path calculation

The model applies 101.44 kPa to the complete 3.102 by 2.101 m projected roof, including the access closure. Applied load is 661.115 kN from those rounded dimensions. All vertical reactions balance this load.

This is a linear beam grillage with idealized rigid joints and equivalent assumed E/G. The source records strip loading, header redistribution, supports and exclusions. Three meshes produce a maximum sampled downward displacement of approximately 0.692 mm. This is bending/torsion response only, not complete roof movement: shear, joint/support compliance, laminate behavior, wall thrust, stability, panels and closure are excluded. No allowable or safety factor is established.

The solver was checked independently against a simply supported uniformly loaded beam. Use the support reactions and element end forces in linear-grillage.json for further joint and support development, not as a fabrication release. Method reference: https://teachbooks.tudelft.nl/computational-modelling/structural_linear/euler_bernouilli.html

Source and revision record

Source: roof-grillage-r1/READ-ME.md

Source SHA-256: 5953957065357e2024170101ce2536b29db5fac34db1f4ba3be96aed25626b8d

Geometry and images describe this development revision. Current product ratings and manufacturing release require separate qualification.

Return to the current product.

Explore the retrofit-only platform and its compatibility, installation and service objectives.

Explore the retrofit